イメージ/測定

Herpes Simplex Virus in buffer

Adsorbed onto silanized glass slide imaged in QI™ mode

最新製品情報

QI™ mode - 測定困難なサンプルを

簡便に測定するNanoWiz­ard® 3 AFM シリーズ用定量イメージング

Atomic Force Microscopy

Accessories for the NanoWizard® AFM (nanowizard accessories)

nanowizard accessoriesAccessories for the NanoWizard® AFM

Accessories for the NanoWizard® AFM
filter:

Where performance meets flexibility

Optical systems/accessories, electrochemistry solutions, electrical sample characterization, environmental control options, software modules, temperature control, acoustic and vibration isolation solutions and more. - JPK provides you with the right accessories to control your sample conditions and to perform successful experiments.

Download accessories handbook

Vortis™ SPMControl station

  • State-of-the-art digital controller with lowest noise levels.
  • High speed 16bit AD conversion with 60 MHz for the photodetector signals
  • 24bit ultra precise ADC with 2.5 MHz

Signal Access Module - SAM

Upgrade for the Vortis™ controller for more flexibility.

ForceRobot® 300 system option

The innovative force spectroscope with fully automated work flow.

See also the product page for more information.

TAO™ Tip Assisted Optics module

Specialized sample stage for advanced experiments combining AFM and optical spectroscopy.

Product note

CellHesion® module

The CellHesion® module combines the capabilities of the BioAFM with precise adhesion force measurements.

See also the product page for more information.

ExperimentPlanner™ software module

For comprehensive planning of an experiment with all of the external parameters.

DirectOverlay™ software module

Perfect integration of optical and AFM data – JPK‘s proprietary and patented solution for perfect overlay of optical and AFM information.
See also the product page for more information.

HyperDrive™ fluid imaging package

For highest resolution imaging of small structured samples in liquid.

Electrical sample connection module

Accommodates electrical conductive samples such as AFM metal stubs by magnetic fixation or transparent samples such as ITO coated glass coverslips.

Conductive AFM (CAFM) module

For conductivity and I/V measurements on the nanoscale.

STM module

The Scanning Tunnelling Microscopy (STM) module fits directly to the NanoWizard® head.

ForceWheel™

JPK‘s ForceWheel™ handheld accessory for most sensitive experiment control, e.g., for force spectroscopy.

Manual precision stage

Offers sub-micron resolution & fine motion control for precise positioning of the AFM tip relative to optical axis and the sample.

Sample holder for large samples

The holder can accommodate larger samples such as microchips or wafers and is equipped with spring clips which can be varied.

Side-view cantilever holder

This holder is designed for use in combination with inverted optical microscopes to observe the cantilever region from the side.

BioCell™ coverslip based liquid cell

Coverslip based fluid cell for Live Cell imaging and single molecule fluorescence with temperature control and perfusion

PetriDishHeater™

  • for Live Cell imaging
  • accomodates 35 mm Petri dishes even with glass bottom

High Temp. Heating Stage - HTHS™

  • polymer science
  • phase separation studies
  • temperature range from ambient to 300°C
  • resolution 0.1°C
  • drift compensated design

Heating Cooling Stage - HCS™

Designed for AFM experiments in air or liquids from 0°C up to 100°C with minimized drift in all dimensions – HCS™ follows the same design criteria as HTHS™.

ECCell™ electrochemistry cell

  • works with transparent or non-transparent substrates
  • temp. range from ambient to 60°C
  • 1200µL liquid volume
  • Product note

Vibration and acoustic isolation

from Accurion, Table Stable and TMC

JPK base for acoustic enclosure

Approved for high performance applications: base frame with top plate from JPK for utmost stability.

TopViewOptics™ with boom stand

The optical system for non transparent samples or substrates such as HOPG, mica, ceramics, implants etc. Can be used in combination with inverted microscopes.

JPK sample holder for small samples

Adaptor for standard sample holder.
Holds magnetically fixed AFM metal stubs.

JPK cantilever changing tool

Probe loading station for convenient cantilever exchange.

Syringe pumps

from KD Scientific and World Precision Instruments (WPI)

Cantilevers, substrates and standards

The JPK platforms are compatible with all commercially available cantilevers.

OEM glove box for NanoWizard® AFMs

The AFM system can be used in a glove box under controlled atmosphere.

Vortis™ Advanced SPMControl station

  • State-of-the-art digital controller with lowest noise levels.
  • 4 high speed 16bit ADC channels with 60 MHz
  • 12 ADCs with 18bit with 800 kHz

Product note

NanoWizard® 3 NanoOptics system option

  • Version with fiber port for fiber SNOM experiments
  • UV transparency version for top/down illumination

See also the product page for more information.

CellHesion® 200 system option

The single cell force testing solution for cell adhesion and elasticity studies.

See also the product page for more information.

BioMaterials Workstation BioMAT™

Completely integrated system comprising upright optical microscope and AFM.

See also the product page for more information.

QI™ Advanced mode

The QI™-Advanced option delivers parameters like adhesion, stiffness, dissipation and more while scanning.
See also the product page for more information.

Advanced Force Spectroscopy module

For advanced force measurement experiments from single protein unfolding, DNA stretching to probing of cells and tissue.

NanoLithography/NanoManipulation module

Software module for NanoWizard® systems.

CoverslipHolder with electr. sample conn.

The CoverslipHolder with electrical sample connection is designed for electrical measurements such as Conductive AFM or STM on a coverslip in combination with high NA optics.

KPM and SCM module

Kelvin Probe (KPM) and Scanning Capacitance (SCM) Microscopy module. Option for nanoscale mapping of surface potential distribution.

CAFM module - enclosed volume

For experiments in inert atmosphere; for conductivity and I/V measurements on the nanoscale under controlled environmental conditions.

High Voltage Sample Bias Amplifier

Can be used for biasing a sample, e.g., in electro-optical experiments or in Piezo-Response Force Microscopy (PFM).

Motorized precision stage

Offers automatic motion control for precise positioning of the sample relative to optical axis and AFM probe.

Standard stage

Offers fine motion control for precise positioning of the AFM tip relative to the sample.

Cantilever holders

  • Standard holder for all-round applications with a large optical field of view
  • Supercut version for use in air or liquids with removable cantilever spring for maximum cleaning results.

Cant. holders for electr. & magnet. Exp.

  • Cantilever holder with electrical tip connection
  • Magnetic field cantilever holder for magnetic actuation

CoverslipHolder

  • closed liquid cell with standard coverslip bottom
  • high-N.A. immersion optics possible
  • autoclavable

SmallCell™ small volume closed liquid cell

The perfect solution for smallest volume experiments in a hermetically sealed environment, two versions available for volumes <150µl and <60µl.

Heating Cooling Module - HCM™

Designed for heating and cooling experiments in gas or liquids with minimized drift in all dimensions.

HCS™ with electrochemistry cell

Designed for electrochemistry AFM experiments with controlled heating and cooling of the sample.

Potentiostats from eDAQ

JPK offers third party potentiostats for electrochemistry applications together with NanoWizard® systems.

JPK acoustic enclosure

Approved for high performance applications: acoustic hood from JPK for utmost stability and isolation.

TopViewOptics™

The optical system for non transparent samples or substrates such as HOPG, mica, ceramics, metall etc.

TopViewOptics™ for inv. opt. microscopes

The optical system for use with inverted optical microscopes or the JPK BioMAT™.

JPK cable anchorage pillow

Heavy weight pillow for fixation of cables to reduce noise coupling.

JPK biocompatible glue

For cantilever or sample fixation, easy removable and biocompatible.

FluidicsModule™

JPK FluidicsModule™ with up to 8 different liquids such as buffer solutions

CCD cameras

JPK supplies CCD cameras from all major manufacturers, e.g., Andor® Technology, Jenoptik, The Imaging Source and IDS Imaging Development Systems.